View Categories

Data Quality Dashboard

This dashboard displays the data sources that Tailpipe uses to generate its carbon emissions calculations. In the interest of transparency, Tailpipe has scored each source on its accuracy, completeness, credibility, conciseness, latency, and plausibility. Tailpipe uses the most up to date and valid data sources available, and has highlighted any improvements to the current data set that it is working to implement in the To Do column.

Key

AccuracyValid, replicable, and reliable.Some gaps in validity, replicability, and reliability, but margins for error have been identified.Gaps in validity, replicability, and reliability, and margins for error cannot be identified.
CompletenessFulfills all parameters.Does not fulfill all parameters, but margins for error have been identified.Does not fulfill all parameters and margins for error cannot be identified.
CredibilitySource is recognized and has been published according to scientific standards (i.e. a journal or research group) or directly from cloud provider.Source is recognized but has not been published according to scientific standards (i.e. a brand/non-profit).Source is not recognized and cannot be traced.
LatencyMethodology sources – Less than 2 years old.
Variable sources – less than 1 month.
Methodology sources – 2-5 years old.
Variable sources – less than 2 months.
Methodology sources – More than 5 years old. Variable sources – more than 2 months.
PlausibilityAligns with Tailpipe’s reasonable assumptions.Sits outside of Tailpipe’s reasonable assumptions.Exceeds Tailpipe’s assumptions significantly.

Amazon Web Services

Updated: 25/11/24

AWS Operational Emissions Data Sources

CategorySourceAccuracyCompletenessCredibilityLatencyPlausibilityImprovementNotes
CPU UtilisationCloudwatchAccuracyCompletenessCredibilityLatencyPlausibilityCustomer must pay for 5 minute updates when making more than 1 million API requests.
Billing & UsageCost and Usage ReportsAccuracyCompletenessCredibilityLatencyPlausibilityAWS retroactively changes the contents of the CUR in line with new data.
CPU Power Teads CPU Power ExtrapolationAccuracyCompletenessCredibilityLatencyPlausibilityAMI testing to validate that Teads data is valid.Based on Teads Engineering testing of 6 instances and extrapolating to all CPUs.
GPU PowerTeads GPU Power DrawAccuracyCompletenessCredibilityLatencyPlausibilityNeeds GPU power sensing on user side – currently no live data.Limited dataset.
RAM PowerTeads testing, plus 5% increment extrapolationAccuracyCompletenessCredibilityLatencyPlausibilityLab testing to verify Teads’ RAM figures.
SSD Power13 drives with capacities from 0.5TB to 8TB
(See Appendix B)
AccuracyCompletenessCredibilityLatencyPlausibilityAssess a wider range of SSD datasheets.
HDD Power71 drives with capacities from 1TB to 24TB
(See Appendix B)
AccuracyCompletenessCredibilityLatencyPlausibility
Motherboard Power 42.5WA1 ElectronicsAccuracyCompletenessCredibilityLatencyPlausibilityFind a published study on motherboard consumption.No demonstrable evidence behind A1 Electronics source, though its statement aligns with other anecdotal evidence.
NICs Power2017 GeekWire Article and NIC manufacturersAccuracyCompletenessCredibilityLatencyPlausibilityFind a more recent source for GBps speed.Unknown which NICs CSPs use.
Network Storage Power2017 GeekWire Article and assumption about 16kWh power drawAccuracyCompletenessCredibilityLatencyPlausibilityFind a more recent source than GeekWire, and better insight into AWS storage server equipment.Based on assumptions and 2017 source.
Intra- and Inter-region NetworkingFicher et al., 2021AccuracyCompletenessCredibilityLatencyPlausibilityFind an inter-region specific study.Research paper only analyzed networking within one country.
External NetworkingCollected research papers, 2014-2021
(See Appendix E)
AccuracyCompletenessCredibilityLatencyPlausibilityFind a more recent study to validate these results.
Power Supply Efficiency Factor 1.12017 GeekWire Article and PSU manufacturersAccuracyCompletenessCredibilityLatencyPlausibility2017 GeekWire article is outdated but manufacturer data provides credibility.
PUE 1.22AWS 2024 blog post citing 2023 IDC reportAccuracyCompletenessCredibilityLatencyPlausibility
Grid Mix – Non-UKEmberAccuracyCompletenessCredibilityLatencyPlausibilityWaiting for Ember to update their dataset to daily or hourly measurements.1 month latency for every country. Unknown which datacenters generate their own power
Grid Mix – UKNational Energy System Operator (UK National Grid)AccuracyCompletenessCredibilityLatencyPlausibility

AWS Embodied Emissions Data Sources

CategorySourceAccuracyCompletenessCredibilityLatencyPlausibilityImprovementNotes
Constant hardware GWP valuesGreen Cloud Computing report, German Environment AgencyAccuracyCompletenessCredibilityLatencyPlausibilityWaiting for German Environment Agency to confirm whether the report will be updated in future.Published in 2021, hardware data potentially becoming outdated.
Variable hardware figures (units, capacity, weight, case type)Boavizta database and AWS specificationsAccuracyCompletenessCredibilityLatencyPlausibilityAdd instance data through testing or available data sources.Crowdsourced data backed up by CSP specifications.
CPU die sizeBoavizta databaseAccuracyCompletenessCredibilityLatencyPlausibilityBuild an independent dataset based on manufacturer data.Crowdsourced data.
RAM densityTechInsights and Semiconductor DigestAccuracyCompletenessCredibilityLatencyPlausibilityFind more data.Independent analysis of RAM hardware.
SSD densityResearcher analysis of hardwareAccuracyCompletenessCredibilityLatencyPlausibilityFind more data.Independent analysis of SSD hardware.
Variable instance figures (instance memory, storage, vCPU)AWS instance specificationsAccuracyCompletenessCredibilityLatencyPlausibility
Instance characteristicsTeads EC2 Instances Carbon Footprint EstimatorAccuracyCompletenessCredibilityLatencyPlausibilityTeads Engineering carried out the first attempt at measuring cloud carbon in 2021. They now collaborate with Boavizta and their database forms the foundation of Boavizta’s data sets.
Network Storage Equipment 2017 GeekWire ArticleAccuracyCompletenessCredibilityLatencyPlausibilityFind updated information on CSP’s network storage servers.

Other AWS Data Sources

CategorySourceAccuracyCompletenessCredibilityLatencyPlausibilityImprovementNotes
Kubernetes hardwareScaleFactory and Teads CPU Power Extrapolation AccuracyCompletenessCredibilityLatencyPlausibilityGet confirmation from CSP about which CPUs are being used; find information on other hardware components.
Serverless hardwareScaleFactory and Teads CPU Power ExtrapolationAccuracyCompletenessCredibilityLatencyPlausibilityGet confirmation from CSP about which CPUs are being used; find information on other hardware components.
Emissions Equivalent Miles DrivenDEFRA Conversion Factors, 2024AccuracyCompletenessCredibilityLatencyPlausibility
Emissions Equivalent Cups of Tea BrewedClever CarbonAccuracyCompletenessCredibilityLatencyPlausibility

Microsoft Azure

Updated: 14/01/25

Azure Operational Emissions Data Sources

CategorySourceAccuracyCompletenessCredibilityLatencyPlausibilityImprovementNotes
CPU UtilisationAzure MonitorAccuracyCompletenessCredibilityLatencyPlausibilityTop N Chart only shows for top 5 virtual machines (VMs), but shows utilization per minute.
Billing & UsageAzure Invoices and Command Line InterfaceAccuracyCompletenessCredibilityLatencyPlausibility
CPU Power Teads CPU Power ExtrapolationAccuracyCompletenessCredibilityLatencyPlausibilityAMI testing to validate that Teads data is valid. Potentially run PowerAPI or other power draw monitor tools.Some estimations and extrapolations were made for certain CPU power draws.
GPU PowerTeads GPU Power Draw or TelegrafAccuracyCompletenessCredibilityLatencyPlausibilityNeeds GPU power sensing on user side.Telegraf tracks in 1 minute intervals, creates new dashboard in Azure monitor.
RAM PowerTeads testing, plus 5% increment extrapolationAccuracyCompletenessCredibilityLatencyPlausibilityLab testing to verify Teads’ RAM figures.Memory usages can be tracked with Azure Monitor.
SSD Power13 drives with capacities from 0.5TB to 8TB
(See Appendix B)
AccuracyCompletenessCredibilityLatencyPlausibilityAssess a wider range of SSD datasheets.
HDD Power71 drives with capacities from 1TB to 24TB
(See Appendix B)
AccuracyCompletenessCredibilityLatencyPlausibility
Motherboard Power 42.5WA1 ElectronicsAccuracyCompletenessCredibilityLatencyPlausibilityFind a published study on motherboard consumption.No demonstrable evidence behind A1 Electronics source, though its statement aligns with other anecdotal evidence.
NICs PowerNIC manufacturer datasheetsAccuracyCompletenessCredibilityLatencyPlausibilityPower draw for MANA NIC is assumed based on similar models.
Network Storage Power2017 GeekWire Article and assumption about 16kWh power drawAccuracyCompletenessCredibilityLatencyPlausibilityFind a more recent source than GeekWire, and more specific to Azure.Based on assumptions and 2017 source.
Intra- and Inter-region NetworkingFicher et al., 2021AccuracyCompletenessCredibilityLatencyPlausibilityFind an inter-region specific study.Research paper only analyzed networking within one country.
External NetworkingCollected research papers, 2014-2021
(See Appendix E)
AccuracyCompletenessCredibilityLatencyPlausibilityFind a more recent study to validate these results.
Power Supply Efficiency Factor 1.12017 GeekWire Article and PSU manufacturersAccuracyCompletenessCredibilityLatencyPlausibility2017 GeekWire article is outdated but manufacturer data provides credibility.
PUE 1.22AWS 2024 blog post citing 2023 IDC reportAccuracyCompletenessCredibilityLatencyPlausibility1.2 figure is an average of the PUE of listed regions.
Grid Mix – Non-UKEmberAccuracyCompletenessCredibilityLatencyPlausibilityWaiting for Ember to update their dataset to daily or hourly measurements.1 month latency for every country. Unknown which datacenters generate their own power
Grid Mix – UKNational Energy System Operator (UK National Grid)AccuracyCompletenessCredibilityLatencyPlausibility

Azure Embodied Emissions Data Sources

CategorySourceAccuracyCompletenessCredibilityLatencyPlausibilityImprovementNotes
Constant hardware GWP valuesGreen Cloud Computing report, German Environment AgencyAccuracyCompletenessCredibilityLatencyPlausibilityWaiting for German Environment Agency to confirm whether the report will be updated in future.Published in 2021, hardware data potentially becoming outdated.
Variable hardware figures (units, capacity, weight, case type)Boavizta database and Azure specificationsAccuracyCompletenessCredibilityLatencyPlausibilityAdd instance data through testing or available data sources.Crowdsourced data backed up by CSP specifications.
CPU die sizeBoavizta databaseAccuracyCompletenessCredibilityLatencyPlausibilityBuild an independent dataset based on manufacturer data.Crowdsourced data.
RAM densityTechInsights and Semiconductor DigestAccuracyCompletenessCredibilityLatencyPlausibilityFind more data.Independent analysis of RAM hardware.
SSD densityResearcher analysis of hardwareAccuracyCompletenessCredibilityLatencyPlausibilityFind more data.Independent analysis of SSD hardware.
Variable instance figures (instance memory, storage, vCPU)Azure instance specificationsAccuracyCompletenessCredibilityLatencyPlausibility
Instance characteristicsAzure InvoicesAccuracyCompletenessCredibilityLatencyPlausibilityFind out how Azure differ workload to CPUs and map which specific CPU is used for each VM.
Network Storage Equipment Azure FilesAccuracyCompletenessCredibilityLatencyPlausibilityFind updated information on CSP’s network storage servers.Information is tangential and only covers data storage during transfer, not its entire storage time.

Other Azure Data Sources

CategorySourceAccuracyCompletenessCredibilityLatencyPlausibilityImprovementNotes
Kubernetes hardwareMicrosoft resource on Cluster deployment & autoscalingAccuracyCompletenessCredibilityLatencyPlausibilityFurther details on how the AutoScaler picks hardware and list of resources it chooses from.Users can define a set of VMs for the node pool.
Serverless hardwareMicrosoft resource on autoscaling and serverlessAccuracyCompletenessCredibilityLatencyPlausibilityFurther details on how the AutoScaler picks hardware and list of resources it chooses from.Azure autoscaling.
Emissions Equivalent Miles DrivenDEFRA Conversion Factors, 2024AccuracyCompletenessCredibilityLatencyPlausibility
Emissions Equivalent Cups of Tea BrewedClever CarbonAccuracyCompletenessCredibilityLatencyPlausibility