Data Quality Dashboard

Overview

This dashboard displays the data sources that Tailpipe uses to generate its carbon emissions calculations. In the interest of transparency, Tailpipe has scored each source on its accuracy, completeness, credibility, conciseness, latency, and plausibility. Tailpipe uses the most up to date and valid data sources available, and has highlighted any improvements to the current data set that it is working to implement in the To Do column.

Key

Quality Dimensions

Accuracy

  • Valid, replicable, and reliable.
  • Some gaps, but margins for error identified.
  • Gaps, and margins for error cannot be identified.

Completeness

  • Fulfills all parameters.
  • Does not fulfill all parameters, but margins identified.
  • Does not fulfill all parameters, margins unidentified.

Credibility

  • Recognized source, published to scientific standards or from CSP.
  • Recognized but not published to scientific standards.
  • Not recognized and cannot be traced.

Latency

  • Methodology: <2 yrs. Variable: <1 month.
  • Methodology: 2–5 yrs. Variable: <2 months.
  • Methodology: >5 yrs. Variable: >2 months.

Plausibility

  • Aligns with Tailpipe's reasonable assumptions.
  • Sits outside Tailpipe's reasonable assumptions.
  • Exceeds Tailpipe's assumptions significantly.

Amazon Web Services

Updated: 22/04/26

AWS Operational Emissions Data Sources

Category Source Acc Comp Cred Lat Plaus Improvement Notes
CPU Utilisation Cloudwatch Customer must pay for 5 minute updates when making more than 1 million API requests.
Billing & Usage Cost and Usage Reports AWS retroactively changes the contents of the CUR in line with new data.
CPU Power Tailpipe's CPU lab-testing (See Processors Methodology) Test an even wider pool of CPUs. Stress tests run on 12 CPUs across 37 instance configurations.
GPU Power Tailpipe's GPU lab-testing (See Appendix A) Two methodologies to distinguish between users with GPU-tracking enabled, and those without. Stress tests run on AMD and NVIDIA GPUs.
RAM Power Tailpipe's RAM stress testing (See Memory Methodology) Test an even wider pool of RAM configurations. Stress tests run on RAM across 37 instance configurations.
SSD Power 13 drives with capacities from 0.5TB to 8TB (See Appendix B) Assess a wider range of SSD datasheets.
HDD Power 71 drives with capacities from 1TB to 24TB (See Appendix B)
Motherboard Power Institute of Electrical and Electronics Engineers, 2021 Source a more recent datacenter power consumption study. Find a published study on maximum motherboard power consumption in datacenter servers.
Network Storage Power AFCOM, 2025 and Seagate, 2024 Based on extrapolations from existing data.
Intra- and Inter-region Networking Ficher et al., 2021 Find an inter-region specific study. Research paper only analyzed networking within one country.
External Networking Collected research papers, 2014-2021 (See Appendix E) Find a more recent study to validate these results.
Power Supply Efficiency Factor 2017 GeekWire Article and PSU manufacturers Replace 2017 GeekWire reference with current manufacturer documentation. 2017 GeekWire article is outdated but manufacturer data provides credibility.
PUE 2024 Amazon Sustainability Report — AWS Summary
Grid Mix - Non-UK Ember Waiting for Ember to update their dataset to daily or hourly measurements. 1 month latency for every country. Unknown which datacenters generate their own power
Grid Mix - UK National Energy System Operator (UK National Grid)

AWS Embodied Emissions Data Sources

Category Source Acc Comp Cred Lat Plaus Improvement Notes
Constant hardware GWP values Green Cloud Computing report, German Environment Agency Waiting for German Environment Agency to confirm whether the report will be updated in future. Published in 2021, hardware data potentially becoming outdated.
Variable hardware figures (units, capacity, weight, case type) Boavizta database and AWS specifications Add instance data through testing or available data sources. Crowdsourced data backed up by CSP specifications.
CPU die size Boavizta database Build an independent dataset based on manufacturer data. Crowdsourced data.
RAM density TechInsights and Semiconductor Digest Find more data. Independent analysis of RAM hardware.
SSD density Researcher analysis of hardware Find more data. Independent analysis of SSD hardware.
Variable virtual machine figures (instance memory, storage, vCPU) AWS instance specifications
Virtual machine characteristics Boavizta API (originally based on Teads Engineering's 2021 carbon footprint estimator) Originally based on Teads Engineering's 2021 EC2 carbon footprint estimator. Data now maintained in the Boavizta database.
Network Storage Equipment Seagate Exos X22 Life Cycle Analysis Find an LCA for the X24 hard drive.

Other AWS Data Sources

Category Source Acc Comp Cred Lat Plaus Improvement Notes
Kubernetes hardware ScaleFactory and Tailpipe's CPU stress testing Get confirmation from CSP about which CPUs are being used; find information on other hardware components.
Serverless hardware ScaleFactory and Tailpipe's CPU stress testing Get confirmation from CSP about which CPUs are being used; find information on other hardware components.
Emissions Equivalent Miles Driven DEFRA Conversion Factors, 2025
Emissions Equivalent Cups of Tea Brewed Clever Carbon

Microsoft Azure

Updated: 22/04/26

Azure Operational Emissions Data Sources

Category Source Acc Comp Cred Lat Plaus Improvement Notes
CPU Utilisation Azure Monitor Top N Chart only shows for top 5 virtual machines (VMs), but shows utilization per minute.
Billing & Usage Azure Invoices and Command Line Interface
CPU Power Tailpipe's CPU lab-testing (See Processors Methodology) Test an even wider pool of CPUs. Stress tests run on 12 CPUs across 37 instance configurations.
GPU Power Tailpipe's GPU lab-testing (See Appendix A) and Telegraf Needs GPU power sensing on user side. Telegraf tracks in 1 minute intervals, creates new dashboard in Azure monitor.
RAM Power Tailpipe's RAM stress testing (See Memory Methodology) Test an even wider pool of RAM configurations. Stress tests run on RAM across 37 instance configurations. Memory usages can be tracked with Azure Monitor.
SSD Power 13 drives with capacities from 0.5TB to 8TB (See Appendix B) Assess a wider range of SSD datasheets.
HDD Power 71 drives with capacities from 1TB to 24TB (See Appendix B)
Motherboard Power Institute of Electrical and Electronics Engineers, 2021 Source a more recent datacenter power consumption study. Find a published study on maximum motherboard power consumption in datacenter servers.
Network Storage Power AFCOM, 2025 and Seagate, 2024 Find a source that is specific to Azure. Based on extrapolations from existing data.
Intra- and Inter-region Networking Ficher et al., 2021 Find an inter-region specific study. Research paper only analyzed networking within one country.
External Networking Collected research papers, 2014-2021 (See Appendix E) Find a more recent study to validate these results.
Power Supply Efficiency Factor PSU manufacturers
PUE Microsoft Datacenter Efficiency
Grid Mix - Non-UK Ember Waiting for Ember to update their dataset to daily or hourly measurements. 1 month latency for every country. Unknown which datacenters generate their own power
Grid Mix - UK National Energy System Operator (UK National Grid)

Azure Embodied Emissions Data Sources

Category Source Acc Comp Cred Lat Plaus Improvement Notes
Constant hardware GWP values Green Cloud Computing report, German Environment Agency Waiting for German Environment Agency to confirm whether the report will be updated in future. Published in 2021, hardware data potentially becoming outdated.
Variable hardware figures (units, capacity, weight, case type) Boavizta database and Azure specifications Add instance data through testing or available data sources. Crowdsourced data backed up by CSP specifications.
CPU die size Boavizta database Build an independent dataset based on manufacturer data. Crowdsourced data.
RAM density TechInsights and Semiconductor Digest Find more data. Independent analysis of RAM hardware.
SSD density Researcher analysis of hardware Find more data. Independent analysis of SSD hardware.
Variable virtual machine figures (instance memory, storage, vCPU) Azure instance specifications
Virtual machine characteristics Azure Invoices Series-to-CPU mapping established for 187 series. Refine to account for multi-CPU series where Azure uses different processors per region.
Network Storage Equipment Azure Files Find updated information on CSP's network storage servers. Information is tangential and only covers data storage during transfer, not its entire storage time.

Other Azure Data Sources

Category Source Acc Comp Cred Lat Plaus Improvement Notes
Kubernetes hardware Microsoft resource on Cluster deployment & autoscaling Further details on how the AutoScaler picks hardware and list of resources it chooses from. Users can define a set of VMs for the node pool.
Serverless hardware Microsoft resource on autoscaling and serverless Further details on how the AutoScaler picks hardware and list of resources it chooses from. Azure autoscaling.
Emissions Equivalent Miles Driven DEFRA Conversion Factors, 2025
Emissions Equivalent Cups of Tea Brewed Clever Carbon