Tailpipe calculates the kilograms of CO2e produced from the organization’s use of cloud computing using the following formula:
Total Emissions = Embodied Emissions + Operational Emissions
Embodied emissions are calculated as:
(((CPU + RAM + SSD + HDD + Motherboard + Power Supply Units + Assembly + Enclosure + Network Storage + Switches) * Disposal) * Time Share * Resource Share)
Operational emissions are calculated as:
((((Instance + Network Storage + Intra-Region Data Transfer + Intra-Region Non-Instance Networking) * PUE) + (Inter-Region Data Transfer + External Data Transfer + Inter-Region Non-Instance Networking + External Non-Instance Networking)) * Carbon Intensity * Power Transmission Losses)
Where:
-
- Instance = (Processors + Accelerators + Memory + Onboard Storage + Motherboard + Network Interface Cards) * Instance Power Supply Efficiency Factor
- Network Storage = ((Power Draw of Provider Network Storage * GB of Network Storage) * Hours of Utilization) * Network Storage Power Supply Efficiency Factor
For more detail, view Tailpipe’s worked examples: